{"id":2296,"date":"2026-04-13T09:10:02","date_gmt":"2026-04-13T09:10:02","guid":{"rendered":"https:\/\/template07.zehannet.net\/?p=2296"},"modified":"2026-04-13T09:10:03","modified_gmt":"2026-04-13T09:10:03","slug":"reliability-in-action-mtu-20v4000-g23-maintenance-at-guilin-bank-financial-building","status":"publish","type":"post","link":"https:\/\/template07.zehannet.net\/tr\/reliability-in-action-mtu-20v4000-g23-maintenance-at-guilin-bank-financial-building\/","title":{"rendered":"Reliability in Action: MTU 20V4000-G23 Maintenance at Guilin Bank Financial Building"},"content":{"rendered":"<p>I read the search intent as&nbsp;<strong>informational first, commercial second<\/strong>, because nobody typing this wants airy marketing language; they want to understand how a named machine, in a named building, is kept ready for the one moment nobody gets a second chance to prepare for, and they probably want enough technical confidence to judge a service vendor, an OEM schedule, or an internal facilities team.<\/p>\n\n\n\n<p>Who is the reader here?<\/p>\n\n\n\n<p>It is the chief engineer, the FM contractor, the procurement manager who inherited a maintenance budget, and the operations lead who knows one ugly truth: in a financial building, backup power is not about comfort, it is about transactions, security systems, elevators, air handling, fire-life-safety coordination, and reputation.<\/p>\n\n\n\n<div class=\"wp-block-rank-math-toc-block\" id=\"rank-math-toc\"><h2>\u0130\u00e7indekiler<\/h2><nav><ul><li><a href=\"#the-search-intent-is-informational-but-it-leans-toward-buying-decisions\">The search intent is informational, but it leans toward buying decisions<\/a><\/li><li><a href=\"#first-hard-truth-20v4000-g23-is-legacy-language-and-that-matters-in-maintenance\">First hard truth: \u201c20V4000-G23\u201d is legacy language, and that matters in maintenance<\/a><\/li><li><a href=\"#reliability-in-a-financial-tower-is-mostly-about-boring-discipline\">Reliability in a financial tower is mostly about boring discipline<\/a><\/li><li><a href=\"#where-mtu-series-4000-maintenance-programs-usually-break-down\">Where MTU Series 4000 maintenance programs usually break down<\/a><\/li><li><a href=\"#the-parts-people-ignore-first-are-usually-the-parts-that-punish-them-later\">The parts people ignore first are usually the parts that punish them later<\/a><\/li><li><a href=\"#the-maintenance-matrix-i-would-run-at-guilin-bank-financial-building\">The maintenance matrix I would run at Guilin Bank Financial Building<\/a><\/li><li><a href=\"#faqs\">SSS<\/a><ul><li><a href=\"#what-is-diesel-generator-maintenance-\">What is diesel generator maintenance?<\/a><\/li><li><a href=\"#how-do-you-maintain-an-mtu-20v4000-g23-generator-\">How do you maintain an MTU 20V4000-G23 generator?<\/a><\/li><li><a href=\"#why-is-load-bank-testing-needed-for-backup-generators-\">Why is load-bank testing needed for backup generators?<\/a><\/li><li><a href=\"#when-should-an-mtu-series-4000-standby-engine-get-a-midlife-check-\">When should an MTU Series 4000 standby engine get a midlife check?<\/a><\/li><li><a href=\"#what-is-the-biggest-mistake-in-backup-generator-maintenance-for-a-financial-building-\">What is the biggest mistake in backup generator maintenance for a financial building?<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"the-search-intent-is-informational-but-it-leans-toward-buying-decisions\">The search intent is informational, but it leans toward buying decisions<\/h2>\n\n\n\n<p>I have seen this pattern for years.<\/p>\n\n\n\n<p>A title like this is built to attract readers who want a maintenance case study, a reliability framework, and enough real-world detail to compare approaches, because they are not asking where to buy a genset; they are asking what \u201cgood maintenance\u201d looks like when the machine is an MTU and the site is a bank-grade facility with almost zero tolerance for hesitation.<\/p>\n\n\n\n<p>That matters, because content that pretends this is transactional will miss the target completely.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"960\" height=\"720\" src=\"https:\/\/template07.zehannet.net\/wp-content\/uploads\/2026\/04\/Guilin-Bank-Financial-Building-1.jpg\" alt=\"Guilin Bank Financial Building\" class=\"wp-image-2298\" title=\"\" srcset=\"https:\/\/template07.zehannet.net\/wp-content\/uploads\/2026\/04\/Guilin-Bank-Financial-Building-1.jpg 960w, https:\/\/template07.zehannet.net\/wp-content\/uploads\/2026\/04\/Guilin-Bank-Financial-Building-1-300x225.jpg 300w, https:\/\/template07.zehannet.net\/wp-content\/uploads\/2026\/04\/Guilin-Bank-Financial-Building-1-768x576.jpg 768w, https:\/\/template07.zehannet.net\/wp-content\/uploads\/2026\/04\/Guilin-Bank-Financial-Building-1-16x12.jpg 16w, https:\/\/template07.zehannet.net\/wp-content\/uploads\/2026\/04\/Guilin-Bank-Financial-Building-1-600x450.jpg 600w\" sizes=\"auto, (max-width: 960px) 100vw, 960px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"first-hard-truth-20v4000-g23-is-legacy-language-and-that-matters-in-maintenance\">First hard truth: \u201c20V4000-G23\u201d is legacy language, and that matters in maintenance<\/h2>\n\n\n\n<p>Names get messy.<\/p>\n\n\n\n<p>MTU\u2019s own Series 4000 nomenclature guide shows that the old&nbsp;<strong>20V4000 G23<\/strong>&nbsp;naming sits in the earlier scheme and maps to the&nbsp;<strong>20V4000 DS2750<\/strong>&nbsp;diesel-system model in the 50 Hz range, while newer Series 4000 naming moves into Gx4 designations; if your service records, parts history, and controller documentation are split across old and new naming, you can lose time on the worst day possible simply because the paperwork is speaking two dialects.<\/p>\n\n\n\n<p>And yes, I think too many teams ignore that.<\/p>\n\n\n\n<p>MTU\u2019s current Series 4000 standby literature still pushes the same broad promises operators care about most, including ISO 8528 alignment, NFPA 110 compatibility, one-step load acceptance, high availability, and long maintenance intervals, but I do not buy the lazy conclusion that \u201clong interval\u201d means \u201clow attention.\u201d It means the platform is designed well. It does not mean your site discipline can drift.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"reliability-in-a-financial-tower-is-mostly-about-boring-discipline\">Reliability in a financial tower is mostly about boring discipline<\/h2>\n\n\n\n<p>No glamour here.<\/p>\n\n\n\n<p>In October 2024, Reuters reported that the United States had already logged\u00a0<strong>1.2 billion outage hours in the first nine months of the year<\/strong>, the worst level Generac said it had seen since it began tracking the measure in 2010, which is another way of saying the outside grid is not becoming polite enough for building engineers to relax.<\/p>\n\n\n\n<p>So what does that mean inside a bank building?<\/p>\n\n\n\n<p>It means the standby diesel set is only one layer in a chain that includes transfer logic, UPS behavior, switchgear, breaker health, fuel condition, battery readiness, and the competence of the people touching the machine; in June 2024, Hong Kong\u2019s KWH said a malfunction in the\u00a0<strong>third-tier UPS backup source<\/strong>\u00a0forced suspension of eight operating theatres, postponed\u00a0<strong>23 elective surgeries<\/strong>, and required transfer of two surgeries, even though the first-tier supply and second-tier backup generators were functioning normally. That is the hard lesson facilities people hate hearing: your generator can be ready, and the building can still fail.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"960\" height=\"720\" src=\"https:\/\/template07.zehannet.net\/wp-content\/uploads\/2026\/04\/Guilin-Bank-Financial-Building-3.jpg\" alt=\"Guilin Bank Financial Building\" class=\"wp-image-2297\" title=\"\" srcset=\"https:\/\/template07.zehannet.net\/wp-content\/uploads\/2026\/04\/Guilin-Bank-Financial-Building-3.jpg 960w, https:\/\/template07.zehannet.net\/wp-content\/uploads\/2026\/04\/Guilin-Bank-Financial-Building-3-300x225.jpg 300w, https:\/\/template07.zehannet.net\/wp-content\/uploads\/2026\/04\/Guilin-Bank-Financial-Building-3-768x576.jpg 768w, https:\/\/template07.zehannet.net\/wp-content\/uploads\/2026\/04\/Guilin-Bank-Financial-Building-3-16x12.jpg 16w, https:\/\/template07.zehannet.net\/wp-content\/uploads\/2026\/04\/Guilin-Bank-Financial-Building-3-600x450.jpg 600w\" sizes=\"auto, (max-width: 960px) 100vw, 960px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"where-mtu-series-4000-maintenance-programs-usually-break-down\">Where MTU Series 4000 maintenance programs usually break down<\/h2>\n\n\n\n<p>I see the same failure pattern.<\/p>\n\n\n\n<p>The engine gets attention when it is loud, smoky, or leaking, but the quiet killers are incomplete logs, low-load exercise that never gets the exhaust hot enough, neglected transfer-switch maintenance, and calendar-age components that \u201clook fine\u201d right up until the first real outage forces them to prove otherwise.<\/p>\n\n\n\n<p>Public guidance built around NFPA 110 is blunt on this point: EPSS equipment, including transfer switches, should be inspected weekly and exercised under load at least monthly for\u00a0<strong>30 minutes<\/strong>; if the building load cannot reach\u00a0<strong>60%<\/strong>\u00a0of generator rated output, a resistive load bank should be used; and a\u00a0<strong>Level 1<\/strong>\u00a0EPSS should be tested for\u00a0<strong>four hours every 36 months<\/strong>. That is not paperwork theater. That is how you avoid wet stacking, false confidence, and the kind of fake readiness that only exists inside a spreadsheet.<\/p>\n\n\n\n<p>Want a harsher example?<\/p>\n\n\n\n<p>In an April 2024 public deficiency notice, a Washington, DC facility was cited after inspectors found no documentation showing its emergency generator was tested monthly under a minimum\u00a0<strong>30% load for 30 minutes<\/strong>, and no available record of an annual load-bank test after\u00a0<strong>April 29, 2022<\/strong>. I bring that up because this is how standby systems actually fail in the field: not by exotic engineering collapse, but by ordinary managerial sloppiness.<\/p>\n\n\n\n<p>And age matters too.<\/p>\n\n\n\n<p>MTU\u2019s own standby-diesel midlife-check material says a Series 4000 standby engine should ideally be assessed at&nbsp;<strong>9 to 12 years old regardless of runtime<\/strong>, which lines up with what experienced operators already know: standby engines age by calendar, seals, coolant chemistry, batteries, controls, and corrosion, not by hour meter alone.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"960\" height=\"720\" src=\"https:\/\/template07.zehannet.net\/wp-content\/uploads\/2026\/04\/Guilin-Bank-Financial-Building-2.jpg\" alt=\"Guilin Bank Financial Building\" class=\"wp-image-2299\" title=\"\" srcset=\"https:\/\/template07.zehannet.net\/wp-content\/uploads\/2026\/04\/Guilin-Bank-Financial-Building-2.jpg 960w, https:\/\/template07.zehannet.net\/wp-content\/uploads\/2026\/04\/Guilin-Bank-Financial-Building-2-300x225.jpg 300w, https:\/\/template07.zehannet.net\/wp-content\/uploads\/2026\/04\/Guilin-Bank-Financial-Building-2-768x576.jpg 768w, https:\/\/template07.zehannet.net\/wp-content\/uploads\/2026\/04\/Guilin-Bank-Financial-Building-2-16x12.jpg 16w, https:\/\/template07.zehannet.net\/wp-content\/uploads\/2026\/04\/Guilin-Bank-Financial-Building-2-600x450.jpg 600w\" sizes=\"auto, (max-width: 960px) 100vw, 960px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"the-parts-people-ignore-first-are-usually-the-parts-that-punish-them-later\">The parts people ignore first are usually the parts that punish them later<\/h2>\n\n\n\n<p>Small leaks grow.<\/p>\n\n\n\n<p>When I audit diesel rooms, I do not just stare at controller screens; I look for the low-drama failures that slowly turn a clean standby machine into a risk, the same patterns you see with a&nbsp;<a href=\"https:\/\/template07.zehannet.net\/tr\/genuine-perkins-1842730c3-crankshaft-front-oil-seal-for-2206-engine-cat-c13-c15-compatible\/\">front crankshaft oil seal on a large diesel engine<\/a>&nbsp;ya da&nbsp;<a href=\"https:\/\/template07.zehannet.net\/tr\/genuine-perkins-t400569-crankshaft-rear-oil-seal-for-1506a-e88tag3-engine\/\">rear oil seal issue in a heavy-duty crankshaft assembly context<\/a>.<\/p>\n\n\n\n<p>Cooling drift is worse.<\/p>\n\n\n\n<p>A tired thermostat, a hardening seal, or a slow coolant loss is exactly the kind of issue teams wave away until jacket-water temperature starts wandering under test, which is why I pay attention to the same maintenance logic behind a&nbsp;<a href=\"https:\/\/template07.zehannet.net\/tr\/genuine-perkins-2485613-thermostat-for-1006tg-tag-series-generator-engines\/\">generator cooling thermostat service item<\/a>&nbsp;and a&nbsp;<a href=\"https:\/\/template07.zehannet.net\/tr\/genuine-perkins-ch10056-thermostat-housing-seal-for-1506a-e88tag3-engine\/\">thermostat housing seal replacement point<\/a>.<\/p>\n\n\n\n<p>Top-end damage is expensive.<\/p>\n\n\n\n<p>Repeated heat cycling, poor coolant control, and half-serious leak response are how people back into bigger work, whether that ends at a&nbsp;<a href=\"https:\/\/template07.zehannet.net\/tr\/genuine-perkins-1885879c1-cylinder-head-gasket-for-1106c-1106a-cat-c6-6-engine\/\">cylinder head gasket under diesel heat stress<\/a>&nbsp;or, after enough neglect, a&nbsp;<a href=\"https:\/\/template07.zehannet.net\/tr\/genuine-perkins-7079597c92-cylinder-liner-kit-for-1106c-1106a-thermostat-valve\/\">cylinder liner kit replacement scenario<\/a>. Different engine family, same ugly maintenance economics.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"the-maintenance-matrix-i-would-run-at-guilin-bank-financial-building\">The maintenance matrix I would run at Guilin Bank Financial Building<\/h2>\n\n\n\n<p>This is the version I trust.<\/p>\n\n\n\n<p>I built the table below from MTU preventive-maintenance guidance, MTU\u2019s Series 4000 standby midlife guidance, and public NFPA 110-style testing guidance; it is the kind of schedule that keeps a financial-building standby set honest instead of merely documented. <\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>System area<\/th><th>What I would check<\/th><th>Trigger \/ frequency<\/th><th>What happens if you skip it<\/th><th>My blunt view<\/th><\/tr><\/thead><tbody><tr><td>Starting system<\/td><td>Batteries, charger output, terminals, auto-start logic<\/td><td>Weekly inspection; loaded exercise at least monthly for 30 minutes <\/td><td>No-start event during outage<\/td><td>A standby diesel that will not crank is just expensive furniture.<\/td><\/tr><tr><td>Cooling circuit<\/td><td>Jacket-water temp trend, coolant chemistry, thermostat behavior, hoses, seepage<\/td><td>Weekly visual plus review during every monthly exercise<\/td><td>Overtemperature, unstable load pickup, gasket stress<\/td><td>Cooling faults almost never arrive dramatically at first.<\/td><\/tr><tr><td>Fuel and combustion<\/td><td>Fuel quality, water contamination, filters, exhaust appearance, load response<\/td><td>Monthly loaded run; deeper review after abnormal smoke or hunting<\/td><td>Wet stacking, incomplete combustion, fouling<\/td><td>Low-load babying is how operators manufacture later trouble.<\/td><\/tr><tr><td>Lubrication and seals<\/td><td>Oil condition, pressure trend, seal seepage, breather condition<\/td><td>Weekly visual; service by OEM schedule<\/td><td>Oil loss, contamination, dirty bay, rising wear<\/td><td>The drip you ignore in March becomes the shutdown in August.<\/td><\/tr><tr><td>ATS and breakers<\/td><td>Transfer timing, contact wear, breaker exercise, control logic<\/td><td>ATS annual maintenance; breaker exercise per guidance, with >600 V breakers on tighter intervals <\/td><td>Power available at the genset but not delivered to the building<\/td><td>This is where \u201cgenerator ran fine\u201d stories are born.<\/td><\/tr><tr><td>Load-bank strategy<\/td><td>Verify real load, exhaust temperature, transient behavior<\/td><td>Use load bank when building load is below 60%; Level 1 four-hour test every 36 months <\/td><td>False confidence, carboning, poor proof under demand<\/td><td>A no-load test is theater, not evidence.<\/td><\/tr><tr><td>Age-based overhaul planning<\/td><td>Controls, mounts, hoses, sensors, rotating wear items, midlife condition review<\/td><td>Midlife check at 9\u201312 years regardless of runtime<\/td><td>Calendar-age failures during a true emergency<\/td><td>Hour meters lie by omission on standby assets.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"faqs\">SSS<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"what-is-diesel-generator-maintenance-\">What is diesel generator maintenance?<\/h3>\n\n\n\n<p>Diesel generator maintenance is the scheduled inspection, testing, servicing, documentation, and age-based replacement work that keeps a standby or prime-power generator able to start, accept load, transfer power, control temperature, and run safely under real electrical demand rather than merely appearing available on paper.<\/p>\n\n\n\n<p>I would add one unfashionable point: it is as much about proof as it is about repair. If the logs are weak, the maintenance is weak.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"how-do-you-maintain-an-mtu-20v4000-g23-generator-\">How do you maintain an MTU 20V4000-G23 generator?<\/h3>\n\n\n\n<p>Maintaining an MTU 20V4000-G23 generator means combining OEM preventive-maintenance practice with site-level weekly inspections, loaded monthly exercising, cooling and lubrication trend checks, transfer-switch verification, fuel-quality control, and a calendar-age review that does not let a standby engine hide behind a low hour meter.<\/p>\n\n\n\n<p>For this model family, I would also reconcile old G23 naming against current Series 4000 documentation first, because parts, service history, and technician assumptions can drift when nomenclature does.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"why-is-load-bank-testing-needed-for-backup-generators-\">Why is load-bank testing needed for backup generators?<\/h3>\n\n\n\n<p>Load-bank testing is a controlled method of applying artificial electrical demand to a generator so technicians can verify output, transfer behavior, exhaust temperature, and sustained performance when the building itself cannot provide enough real load to prove that the standby system is genuinely ready for an outage.<\/p>\n\n\n\n<p>I am opinionated here for a reason: a bank tower with low real standby load can fool itself for years. Public NFPA 110-style guidance says if building load does not exceed 60% of rated output, a resistive load bank should be used.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"when-should-an-mtu-series-4000-standby-engine-get-a-midlife-check-\">When should an MTU Series 4000 standby engine get a midlife check?<\/h3>\n\n\n\n<p>An MTU Series 4000 standby engine should receive a midlife check when it reaches the age window where calendar-related degradation becomes a bigger risk than runtime alone, typically around the ninth to twelfth year, even if the engine has relatively few operating hours recorded.<\/p>\n\n\n\n<p>That is one of the smartest pieces of OEM guidance in this whole category, because standby engines age in silence. MTU says 9 to 12 years regardless of actual runtime.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"what-is-the-biggest-mistake-in-backup-generator-maintenance-for-a-financial-building-\">What is the biggest mistake in backup generator maintenance for a financial building?<\/h3>\n\n\n\n<p>The biggest mistake in backup generator maintenance for a financial building is assuming the engine alone defines reliability, when actual uptime depends on the full emergency-power chain including UPS layers, ATS logic, breakers, controls, batteries, fuel condition, test quality, and the discipline of the people maintaining records.<\/p>\n\n\n\n<p>The 2024 Hong Kong operating-theatre incident is the warning shot I would put in front of every facility owner: the generators were functioning, and the site still had a power-system failure serious enough to disrupt care. (<a href=\"https:\/\/www.info.gov.hk\/gia\/general\/202406\/20\/P2024062000739.htm\" rel=\"nofollow noopener\" target=\"_blank\">Hong Kong Information<\/a>)<\/p>\n\n\n\n<p>If I were responsible for Guilin Bank Financial Building tomorrow morning, I would start with a log audit, not a brochure review. Then I would verify naming, test quality, ATS history, battery health, cooling stability, and calendar age, and I would treat every oily seal, drifting thermostat, and incomplete load record as a reliability issue now, not later. That is how&nbsp;<strong>diesel generator maintenance<\/strong>&nbsp;stops being a maintenance task and becomes an uptime discipline.<\/p>","protected":false},"excerpt":{"rendered":"<p>This is not a brochure piece. It is a hard-nosed look at how MTU 20V4000-G23 maintenance should be handled in a financial building where false confidence is more dangerous than an alarm.<\/p>","protected":false},"author":1,"featured_media":2298,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[33],"tags":[930,927,932,931,929,928],"class_list":["post-2296","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-sourcing-insights","tag-backup-generator-maintenance","tag-diesel-generator-maintenance","tag-financial-building-power-reliability","tag-generator-preventive-maintenance","tag-mtu-20v4000-g23-maintenance","tag-mtu-series-4000-maintenance"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/template07.zehannet.net\/tr\/wp-json\/wp\/v2\/posts\/2296","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/template07.zehannet.net\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/template07.zehannet.net\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/template07.zehannet.net\/tr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/template07.zehannet.net\/tr\/wp-json\/wp\/v2\/comments?post=2296"}],"version-history":[{"count":1,"href":"https:\/\/template07.zehannet.net\/tr\/wp-json\/wp\/v2\/posts\/2296\/revisions"}],"predecessor-version":[{"id":2300,"href":"https:\/\/template07.zehannet.net\/tr\/wp-json\/wp\/v2\/posts\/2296\/revisions\/2300"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/template07.zehannet.net\/tr\/wp-json\/wp\/v2\/media\/2298"}],"wp:attachment":[{"href":"https:\/\/template07.zehannet.net\/tr\/wp-json\/wp\/v2\/media?parent=2296"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/template07.zehannet.net\/tr\/wp-json\/wp\/v2\/categories?post=2296"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/template07.zehannet.net\/tr\/wp-json\/wp\/v2\/tags?post=2296"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}